Data

Spectral reflectance library of healthy and bleached corals in the Keppel Islands, Great Barrier Reef

The University of Queensland
Associate Professor Chris Roelfsema (Aggregated by) Associate Professor Chris Roelfsema (Aggregated by) Professor Stuart Phinn (Aggregated by) Professor Stuart Phinn (Aggregated by)
Viewed: [[ro.stat.viewed]] Cited: [[ro.stat.cited]] Accessed: [[ro.stat.accessed]]
ctx_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rfr_id=info%3Asid%2FANDS&rft_id=https://espace.library.uq.edu.au/view/UQ:734231&rft.title=Spectral reflectance library of healthy and bleached corals in the Keppel Islands, Great Barrier Reef&rft.publisher=The University of Queensland&rft.description=Radiance-reflectance measurements of the main coral types and forms (healthy, dead and bleached) were collected in the Keppel Islands, the Great Barrier Reef Qld, Australia in 2006. Spectral reflectances of 36 samples were recorded in situ. An Ocean Optics USB2000 spectrometer was deployed in a custom made underwater housing with a 0.5 m fibre-optic probe mounted next to an artificial light source. Spectral readings were collected with the probe(bear fibre) about 5 cm from the target to ensure that the target would fill the field of view of the fibre optic (FOV diameter ~4.4 cm), as well as to reduce the attenuating effect of the intermediate water (Roelfsema et al., 2006). Spectral readings included for one target included: 1 reading of the covered spectral fibre to correct for instrument noise, 1 reading of a spectralon panel mounted on the diver's wrist to measure incident ambient light, and six to eight readings of the target. Spectral reflectance was calculated for each target by first subtracting the instrument noise reading from each other reading. The corrected target readings were then divided by the corrected spectralon reading resulting in spectral reflectance of each target reading. An average target spectral reflectance was calculated by averaging six to eight individual spectral reflectances of the target. If an individual target spectral reflectance was visually considered an outlier, it was not included in the average spectral reflectance calculation. See Roelfsema at al. (2006) for additional info on the methodology of underwater spectra collection.&rft.creator=Associate Professor Chris Roelfsema&rft.creator=Associate Professor Chris Roelfsema&rft.creator=Professor Stuart Phinn&rft.creator=Professor Stuart Phinn&rft.date=2017&rft.coverage=151.093721,-23.025584 150.860936,-23.025584 150.860936,-23.222138 151.093721,-23.222138 151.093721,-23.025584&rft_rights=2018, The University of Queensland&rft_rights= http://creativecommons.org/licenses/by/3.0/deed.en_US&rft_subject=eng&rft_subject=Physical Geography and Environmental Geoscience not elsewhere classified&rft_subject=EARTH SCIENCES&rft_subject=PHYSICAL GEOGRAPHY AND ENVIRONMENTAL GEOSCIENCE&rft_subject=Environmental Management&rft_subject=ENVIRONMENTAL SCIENCES&rft_subject=ENVIRONMENTAL SCIENCE AND MANAGEMENT&rft_subject=Environmental Monitoring&rft_subject=Environmental Science and Management not elsewhere classified&rft_subject=Marine and Estuarine Ecology (incl. Marine Ichthyology)&rft_subject=BIOLOGICAL SCIENCES&rft_subject=ECOLOGY&rft.type=dataset&rft.language=English Access the data

Licence & Rights:

Open Licence view details
CC-BY

http://creativecommons.org/licenses/by/3.0/deed.en_US

2018, The University of Queensland

Access:

Open

Contact Information

[email protected]

Full description

Radiance-reflectance measurements of the main coral types and forms (healthy, dead and bleached) were collected in the Keppel Islands, the Great Barrier Reef Qld, Australia in 2006. Spectral reflectances of 36 samples were recorded in situ. An Ocean Optics USB2000 spectrometer was deployed in a custom made underwater housing with a 0.5 m fibre-optic probe mounted next to an artificial light source. Spectral readings were collected with the probe(bear fibre) about 5 cm from the target to ensure that the target would fill the field of view of the fibre optic (FOV diameter ~4.4 cm), as well as to reduce the attenuating effect of the intermediate water (Roelfsema et al., 2006). Spectral readings included for one target included: 1 reading of the covered spectral fibre to correct for instrument noise, 1 reading of a spectralon panel mounted on the diver's wrist to measure incident ambient light, and six to eight readings of the target. Spectral reflectance was calculated for each target by first subtracting the instrument noise reading from each other reading. The corrected target readings were then divided by the corrected spectralon reading resulting in spectral reflectance of each target reading. An average target spectral reflectance was calculated by averaging six to eight individual spectral reflectances of the target. If an individual target spectral reflectance was visually considered an outlier, it was not included in the average spectral reflectance calculation. See Roelfsema at al. (2006) for additional info on the methodology of underwater spectra collection.

Issued: 2017

This dataset is part of a larger collection

Click to explore relationships graph

151.09372,-23.02558 150.86094,-23.02558 150.86094,-23.22214 151.09372,-23.22214 151.09372,-23.02558

150.9773285,-23.123861

ACN 633 798 857