Data

Sensing Science and Engineering Centre (SEC) Vibration Data

Queensland University of Technology
Viewed: [[ro.stat.viewed]] Cited: [[ro.stat.cited]] Accessed: [[ro.stat.accessed]]
ctx_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rfr_id=info%3Asid%2FANDS&rft_id=http://researchdatafinder.qut.edu.au/individual/n10653&rft.title=Sensing Science and Engineering Centre (SEC) Vibration Data&rft.identifier=10378.3/8085/1018.15785&rft.publisher=Queensland University of Technology&rft.description=Two structural columns host the sensors (named A3 and A8) and sensors are mounted on the ceiling slabs of every second floor, i.e. levels 3,5,7 and 9 for both columns.  Most locations measure three axes of acceleration, except for Level 3 Column A8 and Level 7 Column A8 which only measure x axis. Two additional sites are instrumented, a footbridge leading out of the building and a site to monitor the vibration under a Transmission Electron Microscope (TEM). The footbridge has a total of 8 axes simultaneously measured with addition to two Acoustic Emmisions (AE) sensors monitoring the bridge support and mid span. The TEM has a three-axis accelerometer mounted under the concrete and rubber slab the microscope is mounted to and monitors the vibration the microscope is exposed to. Samples are simultaneously sampled at each location and different sample sites are triggered via a central location to minimise clock drift. Data is sampled at 2000 samples per second per axis 24 hours a day, 7 days a week and logged into csv files.  In total there are 31 Axes of data collected throughout the building. Data is uploaded from the data collection server to the storage server in 30 minute intervals.  Data is stored in g's. National Instruments NI-9234 module acquiring data at 2KHz, anti-aliasing filter at 900Hz. Software specifically written to collect, organise and store data onto QUT's storage systems. Time stamped vibration data from multiple locations throughout the Science and Engineering Centre building on the Gardens Point campus of Queensland University of Technology.  Files are stored in Comma Separated Values (.csv).  At approximately 90MB/hour/channel, software is required that can handle large datasets such as Mathworks MATLAB or National Instruments DIAdem. &rft.creator=Anonymous&rft.date=2014&rft.coverage=153.029251,-27.478349&rft_rights=© Queensland University of Technology, 2014.&rft_rights=Creative Commons Attribution 3.0 http://creativecommons.org/licenses/by/3.0/au/&rft_subject=Civil Geotechnical Engineering&rft_subject=ENGINEERING&rft_subject=CIVIL ENGINEERING&rft_subject=Infrastructure Engineering and Asset Management&rft_subject=Spatial Data&rft_subject=Construction Engineering&rft_subject=Civil Engineering not elsewhere classified&rft_subject=Earthquake Engineering&rft_subject=Water Quality Engineering&rft_subject=Transport Engineering&rft_subject=Structural Engineering&rft_subject=Construction Materials&rft_subject=Water Resources Engineering&rft.type=dataset&rft.language=English Access the data

Licence & Rights:

Open Licence view details
CC-BY

Creative Commons Attribution 3.0
http://creativecommons.org/licenses/by/3.0/au/

© Queensland University of Technology, 2014.

Access:

Other view details

Access to the data is mediated by the Visualisation and Interactive Solutions for Engagement and Research (VISER) group. edit

Contact Information

Postal Address:
Visualisation and Interactive Solutions for Engagement and Research (VISER) group
Ph: +61 (0) 420 814 321

viser@qut.edu.au
viser@qut.edu.au

Full description

Two structural columns host the sensors (named A3 and A8) and sensors are mounted on the ceiling slabs of every second floor, i.e. levels 3,5,7 and 9 for both columns.  Most locations measure three axes of acceleration, except for Level 3 Column A8 and Level 7 Column A8 which only measure x axis.

Two additional sites are instrumented, a footbridge leading out of the building and a site to monitor the vibration under a Transmission Electron Microscope (TEM).

The footbridge has a total of 8 axes simultaneously measured with addition to two Acoustic Emmisions (AE) sensors monitoring the bridge support and mid span.

The TEM has a three-axis accelerometer mounted under the concrete and rubber slab the microscope is mounted to and monitors the vibration the microscope is exposed to.

Samples are simultaneously sampled at each location and different sample sites are triggered via a central location to minimise clock drift.

Data is sampled at 2000 samples per second per axis 24 hours a day, 7 days a week and logged into csv files.  In total there are 31 Axes of data collected throughout the building.

Data is uploaded from the data collection server to the storage server in 30 minute intervals.  Data is stored in "g's".

National Instruments NI-9234 module acquiring data at 2KHz, anti-aliasing filter at 900Hz.

Software specifically written to collect, organise and store data onto QUT's storage systems.

Time stamped vibration data from multiple locations throughout the Science and Engineering Centre building on the Gardens Point campus of Queensland University of Technology.  Files are stored in Comma Separated Values (.csv). 

At approximately 90MB/hour/channel, software is required that can handle large datasets such as Mathworks MATLAB or National Instruments DIAdem.

Data time period: 05 07 0006 to 2019

This dataset is part of a larger collection

Click to explore relationships graph

153.02925,-27.47835

153.029251,-27.478349

Identifiers
  • Local : 10378.3/8085/1018.15785