ctx_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rfr_id=info%3Asid%2FANDS&rft_id=info:doi10.5281/zenodo.13625812&rft.title=Multicenter normative data for mesopic microperimetry&rft.identifier=10.5281/zenodo.13625812&rft.publisher=Zenodo&rft.description=This record contains the analysis and underlying data presented in the manuscript Pfau et al. 'Multicenter normative data for mesopic microperimetry'. Contents: 2024-08-30_Multicenter-Normal-Data.csv: Newly published normal data for mesopic microperimetry 2024-08-30_Analysis.R: Analysis script 2024-08-30_Vignette-to-create-normal-data.R: Software example to create normative maps The subfolders Figures and Tables show the analysis results. The folder Intermediary_Results contains the results of the cross-validation folds to assess model performance. To run the analysis code in 2024-08-30_Analysis.R, the following data is needed in addition: Astle et al. Data Brief. 2016 Aug 4;9:673-675. doi: 10.1016/j.dib.2016.07.061 The 2024-08-30_Multicenter-Normal-Data.csv file with the data contains the following columns: source: Describes the clinical site MachineID: ID of the MAIA device used for data collection ParticipantID: ID of the participant EID: ID of the eye eye: Laterality (either Right or Left) sex: Sex (f for female, m for male) age: Age in years ExamID: ID of the exam ExamBaselineID: ID of the corresponding baseline exam (-1 indicates that the exam itself is the baseline exam) GridUsed: Name of the grid falsepos: Rate of false positive responses to Heijl-Krakau stimulus presentations to the optic nerve head (blind spot) bcea63_area_deg2: Fixation stability in terms of the bivariate contour ellipse area covering 63% of the fixation points (in square degree) bcea95_area_deg2: Fixation stability in terms of the bivariate contour ellipse area covering 95% of the fixation points (in square degree) pointID: ID of the test point eccentricity: Eccentricity of the test point (in degree) x_coord: X-coordinate of the test point (in degree), negative values are temporal to the fovea and positive values are nasal to the fovea (in retinal space) y_coord: Y-coordinate of the test point (in degree), negative values are inferior to the fovea and positive values are superior to the fovea (in retinal space) sensitivity: Sensitivity at the test point (in dB)&rft.creator=Pfau, Maximilian &rft.creator=Jolly, Jasleen K &rft.creator=Charng, Jason &rft.creator=von der Emde, Leon &rft.creator=Mueller, Philipp L. &rft.creator=Ansari, Georg &rft.creator=Pfau, Kristina &rft.creator=Chen, Fred K. &rft.creator=Wu, Zhichao &rft.date=2024&rft.type=dataset&rft.language=English Access the data

Access:

Open

Full description

This record contains the analysis and underlying data presented in the manuscript Pfau et al. 'Multicenter normative data for mesopic microperimetry'. Contents: 2024-08-30_Multicenter-Normal-Data.csv: Newly published normal data for mesopic microperimetry 2024-08-30_Analysis.R: Analysis script 2024-08-30_Vignette-to-create-normal-data.R: Software example to create normative maps The subfolders Figures and Tables show the analysis results. The folder Intermediary_Results contains the results of the cross-validation folds to assess model performance. To run the analysis code in 2024-08-30_Analysis.R, the following data is needed in addition: Astle et al. Data Brief. 2016 Aug 4;9:673-675. doi: 10.1016/j.dib.2016.07.061 The 2024-08-30_Multicenter-Normal-Data.csv file with the data contains the following columns: source: Describes the clinical site MachineID: ID of the MAIA device used for data collection ParticipantID: ID of the participant EID: ID of the eye eye: Laterality (either Right or Left) sex: Sex (f for female, m for male) age: Age in years ExamID: ID of the exam ExamBaselineID: ID of the corresponding baseline exam (-1 indicates that the exam itself is the baseline exam) GridUsed: Name of the grid falsepos: Rate of false positive responses to Heijl-Krakau stimulus presentations to the optic nerve head (blind spot) bcea63_area_deg2: Fixation stability in terms of the bivariate contour ellipse area covering 63% of the fixation points (in square degree) bcea95_area_deg2: Fixation stability in terms of the bivariate contour ellipse area covering 95% of the fixation points (in square degree) pointID: ID of the test point eccentricity: Eccentricity of the test point (in degree) x_coord: X-coordinate of the test point (in degree), negative values are temporal to the fovea and positive values are nasal to the fovea (in retinal space) y_coord: Y-coordinate of the test point (in degree), negative values are inferior to the fovea and positive values are superior to the fovea (in retinal space) sensitivity: Sensitivity at the test point (in dB)

Notes

External Organisations
University of Bonn; University of Oxford; University of Basel; University of Melbourne
Associated Persons
Maximilian Pfau (Creator); Jasleen K Jolly (Creator); Leon von der Emde (Creator); Philipp L. Mueller (Creator); Georg Ansari (Creator); Kristina Pfau (Creator); Zhichao Wu (Creator)