Full description
This data set is composed of two test cases for optimal power flow (power flow optimisation in electrical networks). One test case "case2_parallel", shows a second-order cone relaxation gap when using the canonical branch flow model, but not when using the bus injection model. The other test case "case2_gap" shows a significant relaxation gap without total current constraints, and a much lower one with enforcement of total current limits.Lineage: - The case2_parallel is a novel test case.
- case2_gap was inspired by PowerModels.jl's "case5_gap" test case, itself available under BSD license.
Available: 2021-12-14
Data time period: 2021-01-01 to 2021-12-31
Subjects
Engineering |
Electrical Energy Transmission, Networks and Systems |
Electrical Engineering |
matpower |
optimal power flow |
power grid optimisation |
powermodels.jl |
User Contributed Tags
Login to tag this record with meaningful keywords to make it easier to discover
Identifiers
- DOI : 10.25919/ZNC4-5Z12
- Handle : 102.100.100/433386
- URL : data.csiro.au/collection/csiro:53173