Data

Images used to calculate the image resolution of images taken at the Australian Nuclear Science and Technology Organization

Macquarie University
Joseph J. Bevitt (Aggregated by) Paritosh Giri (Aggregated by) Simon Clark (Aggregated by) Vili Grigorova (Aggregated by)
Viewed: [[ro.stat.viewed]] Cited: [[ro.stat.cited]] Accessed: [[ro.stat.accessed]]
ctx_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rfr_id=info%3Asid%2FANDS&rft_id=info:doi10.25949/24171879.v1&rft.title=Images used to calculate the image resolution of images taken at the Australian Nuclear Science and Technology Organization&rft.identifier=https://doi.org/10.25949/24171879.v1&rft.publisher=Macquarie University&rft.description=The dataset comprises images of a phantom captured using various configurations at the DINGO beamline at ANSTO. These files encompass bright and dark field images and phantom images. An accompanying Excel spreadsheet also offers details regarding the data, including image names and the corresponding acquisition setups.The lenses used are Zeiss Ikon Makro-Planar (MP) 50 with 50 mm focal length and Zeiss Ikon Makro-Planar (MP) 100 with 100 mm focal length. The images were taken with both high-resolution and high-intensity flux. Two screens were used: ZnS(Ag)/6LiF with 100 and 200 μm scintillator screens and Gd2O2S:Tb with 20 and 30 μm scintillator screens.&rft.creator=Joseph J. Bevitt&rft.creator=Paritosh Giri&rft.creator=Simon Clark&rft.creator=Vili Grigorova&rft.date=2023&rft_rights=CC-BY&rft_subject=Modulation transfer function (MTF)&rft_subject=Image processing Data processing&rft_subject=Neutron Tomography&rft_subject=Neutron Imaging&rft_subject=image resolution methodology&rft_subject=Image Resolution&rft_subject=Other physical sciences not elsewhere classified&rft.type=dataset&rft.language=English Access the data

Licence & Rights:

Open Licence view details
CC-BY

CC-BY

Full description

The dataset comprises images of a phantom captured using various configurations at the DINGO beamline at ANSTO. These files encompass bright and dark field images and phantom images. An accompanying Excel spreadsheet also offers details regarding the data, including image names and the corresponding acquisition setups.

The lenses used are Zeiss Ikon Makro-Planar (MP) 50 with 50 mm focal length and Zeiss Ikon Makro-Planar (MP) 100 with 100 mm focal length. The images were taken with both high-resolution and high-intensity flux. Two screens were used: ZnS(Ag)/6LiF with 100 and 200 μm scintillator screens and Gd2O2S:Tb with 20 and 30 μm scintillator screens.


Issued: 2023-09-22

Created: 2023-09-22

This dataset is part of a larger collection

Click to explore relationships graph
Subjects

User Contributed Tags    

Login to tag this record with meaningful keywords to make it easier to discover

Identifiers