Data

Human neck stiffness and range of motion - methods and repeatability resource materials: moment-angle data

Adelaide University
Liu, Mingyue ; Quarrington, Ryan ; Robertson, Will ; Sandoz, Baptiste ; Jones, Claire
Viewed: [[ro.stat.viewed]] Cited: [[ro.stat.cited]] Accessed: [[ro.stat.accessed]]
ctx_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rfr_id=info%3Asid%2FANDS&rft_id=info:doi10.25909/27922983.v1&rft.title=Human neck stiffness and range of motion - methods and repeatability resource materials: moment-angle data&rft.identifier=10.25909/27922983.v1&rft.publisher=The University of Adelaide&rft.description=This dataset contains moment-angle data collected from three male (Male1-3) and three female (Female1-3) participants during passive-lying tests.Each tab in the spreadsheet represents the moment-angle data from a single trial, named using the format ‘[session number]_[motion][trial number]’, where:Session number: S1 (Session 1), S2 (Session 2).Motion:F: FlexionE: ExtensionL: Left lateral bendingR: Right lateral bendingRL: Left axial rotationRR: Right axial rotationTrial number: 1–5, corresponding to trials 1 through 5.In each spreadsheet, the first column (angle) represents the head-torso rotational angle in the tested direction, measured in degrees. The second column (moment) contains the applied moment on the participant’s neck, in units of Nm/degree.The manuscript provides comprehensive details on the testing protocol, data collection procedures, and post-processing methods. Participant anthropometric data are included in the ParticipantInformation.xlsx file. Participant identifications are color-coded consistently with the published manuscript:Liu M, Quarrington RD, Sandoz B, Robertson WSP, Jones CF. Evaluation of Apparatus and Protocols to Measure Human Passive Neck Stiffness and Range of Motion. Ann Biomed Eng. 2024 Aug;52(8):2178–2192. doi: 10.1007/s10439-024-03517-w. Epub 2024 Apr 24. PMID: 38658477; PMCID: PMC11247060.&rft.creator=Liu, Mingyue &rft.creator=Quarrington, Ryan &rft.creator=Robertson, Will &rft.creator=Sandoz, Baptiste &rft.creator=Jones, Claire &rft.edition=1&rft_rights= https://creativecommons.org/licenses/by-nc-sa/4.0/&rft_subject=Biomechanical engineering&rft_subject=Orthopaedics&rft_subject=Biomechanics&rft_subject=cervical spine&rft_subject=spine&rft_subject=stiffness&rft_subject=flexibility&rft_subject=range of motion (ROM)&rft_subject=apparatus&rft_subject=repeatability&rft.type=dataset&rft.language=English Access the data

Licence & Rights:

Other view details

Full description

This dataset contains moment-angle data collected from three male (Male1-3) and three female (Female1-3) participants during passive-lying tests.

Each tab in the spreadsheet represents the moment-angle data from a single trial, named using the format ‘[session number]_[motion][trial number]’, where:

  • Session number: S1 (Session 1), S2 (Session 2).
  • Motion:
    • F: Flexion
    • E: Extension
    • L: Left lateral bending
    • R: Right lateral bending
    • RL: Left axial rotation
    • RR: Right axial rotation
  • Trial number: 1–5, corresponding to trials 1 through 5.

In each spreadsheet, the first column (angle) represents the head-torso rotational angle in the tested direction, measured in degrees. The second column (moment) contains the applied moment on the participant’s neck, in units of Nm/degree.

The manuscript provides comprehensive details on the testing protocol, data collection procedures, and post-processing methods. Participant anthropometric data are included in the ParticipantInformation.xlsx file. Participant identifications are color-coded consistently with the published manuscript:

Liu M, Quarrington RD, Sandoz B, Robertson WSP, Jones CF. Evaluation of Apparatus and Protocols to Measure Human Passive Neck Stiffness and Range of Motion. Ann Biomed Eng. 2024 Aug;52(8):2178–2192. doi: 10.1007/s10439-024-03517-w. Epub 2024 Apr 24. PMID: 38658477; PMCID: PMC11247060.


This dataset is part of a larger collection

Click to explore relationships graph
Subjects

User Contributed Tags    

Login to tag this record with meaningful keywords to make it easier to discover

Identifiers
ACN 633 798 857