Brief description
Annual hourly air quality and meteorological data by monitoring site for the 2018 calendar year. For more information on air quality, including live air data, please visit [https://www.qld.gov.au/environment/pollution/monitoring/air](https://www.qld.gov.au/environment/pollution/monitoring/air).**Data resolution:** One-hour average values (one-hour sum for rainfall)
**Data row timestamp:** Start of averaging period
**Missing data/not monitored:** Blank cell
**Calm conditions:** No hourly average wind direction is reported when the hourly average wind speed is zero
**Barometric pressure:** Values are at monitoring station elevation, not corrected to mean sea level
**Daily zero/span response check:** Automated instrument zero/span response checks are conducted daily between midnight and 1am at Queensland Government sites (can differ at industry sites). Where this takes place an ambient hourly value cannot be reported.
**Sampling height:** Four metres above ground (unless otherwise indicated)
Full description
Aldoga (Gladstone) 2018 hourly meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -23.8409; Longitude: 151.0627 \r\n**AS/NZS 3580.1.1 site classification:** Background \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Temperature and relative humidity sensors located 10 metres above ground level.\r\n* Rainfall measured by acoustic sensor.\r\n\r\n**Wind:** Ultrasonic sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value.\r\n \r\n**Temperature:** Capacitive ceramic sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Barometric pressure:** Capacitive silicon sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n\r\nAbbot Point (Bowen) 2018 hourly meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -19.9496; Longitude: 148.0482 \r\n**AS/NZS 3580.1.1 site classification:** Background \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Temperature and relative humidity sensors located 10 metres above ground level.\r\n* Rainfall measured by acoustic sensor.\r\n\r\n**Wind sensor:** Ultrasonic sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +8 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacitive ceramic sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Barometric pressure:** Capacitive silicon sensor. \r\n\r\n* Height above ground level: 10 metres.
Auckland Point (Gladstone) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -23.8349; Longitude: 151.2539 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Located on southern side of slope below a ridge. \r\n* Trees within 20 metres of the monitoring site. \r\n* Temperature and relative humidity sensors located 10 metres above ground level.\r\n* Rainfall measured by acoustic sensor. \r\n\r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacitive ceramic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Barometric pressure:** Capacitive silicon sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**PM10:** Tapered Element Oscillating Microbalance (TEOM) Model 1405 operated in accordance with AS/NZS 3580.9.16 (excluding FDMS requirements)\r\n\r\n* Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter. \r\n* Reported concentrations are uncorrected instrument output values. \r\n* Negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.. \r\n\r\n
Boat Creek (Gladstone) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -23.8200; Longitude: 151.1539 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies fully \r\n\r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacitive ceramic sensor \r\n**Relative humidity:** Capacitive thin film polymer sensor \r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1\r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data.\r\n\r\n**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1\r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13 \r\n\r\n* The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter. \r\n* Reported concentrations are uncorrected instrument output values. \r\n* The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.\r\n* Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported. \r\n\r\n**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1\r\n\r\n* Detector spectral response centred at 530 nm. \r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data.
Boyne Island (Gladstone) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -23.9408; Longitude: 151.3507 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Located on eastern side of slope below a ridge running north-south. \r\n* Trees within 20 metres of the monitoring site. \r\n\r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacitive ceramic sensor \r\n**Relative humidity:** Capacitive thin film polymer sensor\r\n \r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1\r\n \r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1 \r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**Carbon monoxide:** Infrared absorption analyser operated in accordance with AS 3580.7.1\r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13 \r\n\r\n* The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter. \r\n* Reported concentrations are uncorrected instrument output values. \r\n* The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.\r\n* Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported. \r\n\r\n**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1\r\n\r\n* Detector spectral response centred at 530 nm. \r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data.
Brisbane CBD (South East Queensland) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -27.4774; Longitude: 153.0281 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies, except for: \r\n\r\n* Equipment located in room on sixth floor of building. \r\n* Nephelometer inlet located on eastern side of building, 1 metre out from building. \r\n* PM10 inlet located on building roof above equipment room, 1 metre above roof surface. \r\n* Building lift shaft higher than PM10 inlet located 8 metres south of inlet.\r\n \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, with exceptions: \r\n\r\n* Building lift shaft higher than wind sensor and within 10 metres of sensor. \r\n* Buildings higher than wind sensor located within 40 metres of sensor. \r\n\r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above roof level: 4 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacitive ceramic sensor\r\n\r\n* Height above roof level: 4 metres. \r\n\r\n**Relative humidity**: Capacitive thin film polymer sensor \r\n\r\n* Height above roof level: 4 metres \r\n\r\n**Rainfall**: Vaisala RAINCAP® precipitation sensor\r\n\r\n* Height above roof level: 4 metres \r\n\r\n**Barometric pressure**: Capacitive silicon sensor\r\n\r\n* Height above roof level: 4 metres \r\n \r\n**PM10:** Tapered Element Oscillating Balance (TEOM) Model 1405-F fitted with Filter Dynamics Measurement System operated in accordance with AS/NZS 3580.9.16 \r\n\r\n* The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter. \r\n* Reported concentrations are uncorrected instrument output values. \r\n* The reported PM10 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.\r\n* Negative hourly PM10 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.\r\n\r\n**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1\r\n\r\n* Detector spectral response centred at 530 nm. \r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data.
Burncluith (South West Queensland) 2018 hourly air quality and meteorological data - **Industry-operated monitoring site:** Data presented as received by Queensland Government \r\n**Period of operation:** 1 January to 18 July 2018 (station closed) (NO, NOx measurements supplied from 1 March 2018) \r\n**Site location:** 20 km north-east of Chinchilla \r\n**AS/NZS 3580.1.1 site classification:** Background \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies, except for:\r\n\r\n* A house chimney is within 50m south-east of the monitoring station inlet\r\n* Trees within 10m north of monitoring station\r\n\r\n**Ozone:** Ultraviolet photometry analyser operated in accordance with AS 3580.6.1 \r\n\r\n* Sampling inlet height above ground level: 10 metres\r\n\r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1 \r\n\r\n* Sampling inlet height above ground level: 10 metres\r\n\r\n**Carbon Monoxide:** Infrared absorption analyser operated in accordance with AS 3580.7.1 \r\n\r\n* Sampling inlet height above ground level: 10 metres
Cannon Hill (South East Queensland) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -27.4654; Longitude: 153.0872 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Temperature and relative humidity sensors located 10 metres above ground level. \r\n* Rainfall measured by acoustic sensor \r\n\r\n**Wind sensor:** Ultrasonic sensor \r\n\r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacitive ceramic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n \r\n**Relative humidity:** Capacitive thin film polymer sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Barometric pressure:** Capacitive silicon sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1 \r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data.\r\n\r\n**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13 \r\n\r\n* The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter. \r\n* Reported concentrations are uncorrected instrument output values. \r\n* The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.\r\n* Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.\r\n\r\n**TSP:** Tapered Element Oscillating Microbalance (TEOM) Model 1405 fitted with TSP inlet and operated in accordance with AS/NZS 3580.9.13 (excluding FDMS requirements) \r\n\r\n* Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter. \r\n* Reported concentrations are uncorrected instrument output values. \r\n* Negative hourly TSP concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3. \r\n\r\n\r\n
Clinton (Gladstone) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -23.8701; Longitude: 151.2216 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:\r\n \r\n* Wind, temperature, relative humidity, rainfall and barometric pressure sensors located 10 metres above ground level.\r\n* Rainfall measured by acoustic sensor\r\n\r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres.\r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacitive ceramic sensor. \r\n\r\n* Height above ground level: 10 metres.\r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor. \r\n\r\n* Height above ground level: 10 metres.\r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor. \r\n\r\n* Height above ground level: 10 metres.\r\n\r\n**Barometric pressure:** Capacitive silicon sensor. \r\n\r\n* Height above ground level: 10 metres.\r\n\r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1 \r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1\r\n \r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13\r\n \r\n* The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter. \r\n* Reported concentrations are uncorrected instrument output values. \r\n* The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.\r\n* Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported. \r\n\r\n**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1\r\n\r\n* Detector spectral response centred at 530 nm. \r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n\r\n
Deception Bay (South East Queensland) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -27.1935; Longitude: 153.0347 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Trees within 20m to the south-west of the monitoring station \r\n \r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value. \r\n\r\n**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1\r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1\r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n\r\n
Fisherman Island (South East Queensland) 2018 hourly air quality and meteorological data - **Period of operation:** 7 December (site commissioned) to 31 December 2018 \r\n**Site location:** Latitude: -23.3833; Longitude: 153.1623 \r\n**AS/NZS 3580.1.1 site classification:** Peak (industry) \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for:\r\n\r\n* Temperature and relative humidity sensors located 10 metres above ground level.\r\n* Rainfall measured by acoustic sensor\r\n\r\n**Wind:** Ultrasonic sensor\r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.\r\n\r\n**Temperature:** Capacitive ceramic sensor.\r\n\r\n* Height above ground level: 10 metres.\r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor. \r\n\r\n* Height above ground level: 10 metres.\r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor. \r\n\r\n* Height above ground level: 10 metres.\r\n\r\n**Barometric pressure:** Capacitive silicon sensor.\r\n\r\n* Height above ground level: 10 metres.\r\n\r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1\r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n\r\n
Fisherman's Landing (Gladstone) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -23.7937; Longitude: 151.1601 \r\n**AS/NZS 3580.1.1 site classification:** Peak (industry) \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies, except for:\r\n\r\n* situated within 10 metres of edge of unsealed road \r\n\r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Temperature and relative humidity sensors located 10 metres above ground level.\r\n* Rainfall measured by acoustic sensor \r\n\r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres.\r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacitive ceramic sensor. \r\n\r\n* Height above ground level: 10 metres.\r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor. \r\n\r\n* Height above ground level: 10 metres.\r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor. \r\n\r\n* Height above ground level: 10 metres.\r\n\r\n**Barometric pressure:** Capacitive silicon sensor. \r\n\r\n* Height above ground level: 10 metres.\r\n\r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1 \r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1 \r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**Methane:** Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) operated in accordance with AS/NZS 3580.17 (not operational in 2018) \r\n\r\n**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13 \r\n\r\n* The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter. \r\n* Reported concentrations are uncorrected instrument output values. \r\n* The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals. \r\n* Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported. \r\n\r\n**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1 \r\n\r\n* Detector spectral response centred at 530 nm. \r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**Black carbon (PM10 size fraction):** Model 5012 Multi-Angle Absorption Photometer operated in accordance with the manufacturer's instructions. \r\n\r\n* Fitted with PM10 size-selective inlet \r\n\r\n\r\n
Flinders View (Ipswich, South East Queensland) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -27.6529; Longitude: 152.7739 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies, except for: \r\n\r\n* Trees above the height of inlet within 10 metres of the monitoring site.\r\n\r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Located on western side of slope below a ridge running northeast-southeast.\r\n* Trees within 10 metres of the monitoring site (below height of wind sensor).\r\n* Temperature and relative humidity sensors located 10 metres above ground level. \r\n* Rainfall measured by acoustic sensor\r\n\r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacitive ceramic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Barometric pressure:** Capacitive silicon sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1 \r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1 \r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with S/NZS 3580.4.1\r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**PM10:** Tapered Element Oscillating Microbalance (TEOM) Model 1405 operated in accordance with AS/NZS 3580.9.16 (excluding FDMS requirements) \r\n\r\n* Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter. \r\n* Reported concentrations are uncorrected instrument output values. \r\n* Negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.\r\n\r\n**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1\r\n\r\n* Detector spectral response centred at 530 nm. \r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data.
Gatton (South East Queensland) 2018 hourly meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -27.5457; Longitude: 152.3288 \r\n**AS/NZS 3580.1.1 site classification:** Background \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Temperature and relative humidity sensors located 10 metres above ground level.\r\n* Rainfall measured by acoustic sensor\r\n\r\n**Wind:** Ultrasonic sensor\r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacitive ceramic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Barometric pressure:** Capacitive silicon sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n\r\n
Hopeland (South West Queensland) 2018 hourly air quality and meteorological data - **Industry-operated monitoring site:** Data presented as received by Queensland Government \r\n**Period of operation:** 1 January to 31 December 2018 (NO, NOx, CO2, CH4 measurements supplied from 1 March 2018) \r\n**Site location:** Within 5 km of Hopeland town centre \r\n**AS/NZS 3580.1.1 site classification:** Background \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies \r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Temperature:** Solid state thermistor sensor \r\n\r\n* Height above ground level: 2 metres. \r\n\r\n**Rain:** Tipping bucket rain gauge \r\n**Relative humidity:** Capacitive thin film polymer sensor \r\n\r\n* Height above ground level: 2 metres.\r\n\r\n**Solar radiation:** Pyranometer \r\n**Ozone:** Ultraviolet photometry analyser operated in accordance with AS 3580.6.1 \r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1 \r\n**Carbon Monoxide:** Infrared absorption analyser operated in accordance with AS 3580.7.1 \r\n**Carbon dioxide/Methane:** Cavity ring-down spectroscopic method operated in accordance with AS 3580.17 \r\n**PM10/PM2.5/TSP:** Optical light scattering method using Palas Fidas 200 instrument. \r\n\r\n\r\n
Josephville (South East Queensland) 2018 hourly meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -27.9962; Longitude: 152.9257 \r\n**AS/NZS 3580.1.1 site classification:** Background \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Temperature and relative humidity sensors located 10 metres above ground level.\r\n* Rainfall measured by acoustic sensor. \r\n \r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value. \r\n \r\n**Temperature:** Capacitive ceramic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Barometric pressure:** Capacitive silicon sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n
Lytton (South East Queensland) 2018 hourly air quality and meteorological data - **Industry-operated monitoring site:** Data presented as received by Queensland Government \r\n**Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -27.4064; Longitude: 153.1527 \r\n**AS/NZS 3580.1.1 site classification:** Peak (industry) \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14 compliance (meteorology)** : Complies, except for: \r\n \r\n* Temperature and relative humidity sensors located 10 metres above ground level.\r\n* Rainfall measured by acoustic sensor. \r\n \r\n**Wind sensor:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Temperature:** Capacitive ceramic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Barometric pressure:** Capacitive silicon sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1 \r\n**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-D operated in accordance with AS/NZS 3580.9.13 (excluding FDMS requirements) \r\n\r\n* Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.\r\n* Reported concentrations are uncorrected instrument output values. \r\n* Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.\r\n\r\n\r\n
Memorial Park (Gladstone) 2018 hourly air quality data - **Period of operation:** 1 January to 31 December 2018\r\n**Site location:** Latitude: -23.8426; Longitude: 151.2534\r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies, except for: \r\n\r\n* DOAS light path between 4 metres and 25 metres above ground level. \r\n\r\n**Ozone, nitrogen dioxide, sulfur dioxide, benzene, toluene, xylenes (total) and formaldehyde:** Differential Optical Absorption Spectroscopy (DOAS) analyser operated in accordance with AS/NZS 3580.15 \r\n\r\n* Reported value is average concentration over 520 metre light path running southwest-northeast from Memorial Park (-23.8443, 151.2517) to the Gladstone Entertainment Centre (-23.8409,151.2550). \r\n* Instrument output offset and/or scaled based on instrument calibration data. \r\n
Menzies (Mount Isa) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -20.7167; Longitude: 139.4920 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies, except for: \r\n\r\n* Trees above height of inlet within 10 metres of monitoring site. \r\n\r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Trees within 10 metres of monitoring site. \r\n\r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +6 degrees to the sensor output value. \r\n\r\n**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1\r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n
Miles Aiport (South West Queensland) 2018 hourly air quality and meteorological data - **Industry-operated monitoring site:** Data presented as received by Queensland Government \r\n**Period of operation:** 1 January to 31 December 2018 (NO, NOx, CO2, CH4 measurements supplied from 1 March 2018) \r\n**Site location:** 3.5 km east of Miles Airport \r\n**AS/NZS 3580.1.1 site classification:** Background \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies \r\n**Temperature:** Solid state thermistor sensor \r\n\r\n* Height above ground level: 2 metres.\r\n\r\n**Wind:** Ultrasonic sensor\r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Rain:** Tipping bucket rain gauge \r\n**Relative humidity:** Capacitive thin film polymer sensor \r\n\r\n* Height above ground level: 2 metres. \r\n\r\n**Solar radiation:** Pyranometer \r\n**Ozone:** Ultraviolet photometry analyser operated in accordance with AS 3580.6.1 \r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1 \r\n**Carbon Monoxide:** Infrared absorption analyser operated in accordance with AS 3580.7.1 \r\n**Carbon dioxide/Methane:** Cavity ring-down spectroscopic method operated in accordance with AS 3580.17 \r\n**PM10/PM2.5/TSP:** Optical light scattering method using Palas FIDAS 200 instrument
Moranbah (Moranbah) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -21.9995; Longitude: 148.0713 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies fully \r\n\r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +8 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacitive ceramic sensor \r\n**PM10:** Tapered Element Oscillating Balance (TEOM) Model 1405 operated in accordance with AS/NZS 3580.9.16 (excluding FDMS requirements)\r\n\r\n* Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.\r\n* Reported concentrations are uncorrected instrument output values.\r\n* Negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.\r\n\r\n
Mountain Creek (Sunshine Coast, South East Queensland) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -26.6918; Longitude: 153.1044 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies fully \r\n \r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacitive ceramic sensor \r\n**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1 \r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1 \r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data.\r\n \r\n* Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter. \r\n* Reported concentrations are uncorrected instrument output values. \r\n* Negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3. \r\n\r\n**PM10:** Tapered Element Oscillating Microbalance (TEOM) Model 1405 operated in accordance with AS/NZS 3580.9.16 (excluding FDMS requirements) \r\n\r\n* Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.\r\n* Reported concentrations are uncorrected instrument output values. \r\n* Negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.\r\n\r\n**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1 \r\n\r\n* Detector spectral response centred at 530 nm. \r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n
Mutdapilly (South East Queensland) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -27.7530; Longitude: 152.6510 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for \r\n\r\n* Temperature and relative humidity sensors located 10 metres above ground level. \r\n* Rainfall measured by acoustic sensor. \r\n\r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value. \r\n\r\n**Temperature (from 4 January 2018):** Capacitive ceramic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Relative humidity (from 4 January 2018):** Capacitive thin film polymer sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Rainfall (from 4 January 2018):** Vaisala RAINCAP® precipitation sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Barometric pressure (from 4 January 2018):** Capacitive silicon sensor \r\n\r\n* Height above ground level: 10 metres.\r\n\r\n**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1\r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1\r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n
North Maclean (South East Queensland) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -27.7709; Longitude: 153.0301 \r\n**AS/NZS 3580.1.1 site classification:** Background \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Temperature and relative humidity sensors located 10 metres above ground level.\r\n* Rainfall measured by acoustic sensor. \r\n\r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres.\r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value. \r\n \r\n**Temperature:** Capacitive ceramic sensor \r\n\r\n* Height above ground level: 10 metres.\r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor \r\n\r\n* Height above ground level: 10 metres.\r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor. \r\n\r\n* Height above ground level: 10 metres.\r\n\r\n**Barometric pressure:** Capacitive silicon sensor. \r\n\r\n* Height above ground level: 10 metres.\r\n\r\n**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1 \r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data.\r\n \r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1 \r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data.
North Ward (Townsville) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018\r\n**Site location** Latitude: -19.2509; Longitude: 146.8073 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies, except for: \r\n\r\n* Isolated trees above height of inlet within 10 metres west of the monitoring site.\r\n \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Isolated trees within 10 metres west of the monitoring site.\r\n* Temperature and relative humidity sensors located 10 metres above ground level.\r\n* Rainfall measured by acoustic sensor.\r\n\r\n**Wind sensor:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +8 degrees to the sensor output value.\r\n\r\n**Temperature:** Capacitive ceramic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor\r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Barometric pressure:** Capacitive silicon sensor\r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1 \r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1\r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data.\r\n\r\n**PM10/PM2.5:** Scattered light spectrometry (TAPI Model 640X) operated in accordance with USEPA equivalence method designation requirements\r\n\r\n* Reported concentrations are uncorrected instrument output values. \r\n\r\n**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1\r\n\r\n* Detector spectral response centred at 520 nm. \r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data.\r\n \r\n**Updated: 02/10/2019:** North Ward PM10 and PM2.5 measurements corrected to standard conditions of 0°C and 1013.25kPa
Rocklea (South East Queensland) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -27.5358; Longitude: 152.9934 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies, except for: \r\n\r\n* Isolated trees above height of inlet within 10 metres west of the monitoring site. \r\n\r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Isolated trees within 10 metres west of the monitoring site. \r\n* Temperature and relative humidity sensors located 10 metres above ground level.\r\n* Rainfall measured by acoustic sensor. \r\n\r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacitive ceramic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Barometric pressure:** Capacitive silicon sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Solar radiation:** Pyranometer \r\n**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1\r\n \r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1\r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13 \r\n\r\n* The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter. \r\n* Reported concentrations are uncorrected instrument output values. \r\n* The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.\r\n* Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported. \r\n\r\n**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1 \r\n\r\n* Detector spectral response centred at 520 nm. \r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data.\r\n
South Brisbane (South East Queensland) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018\r\n**Site location:** Latitude: -27.4848; Longitude: 153.0321 \r\n**AS/NZS 3580.1.1 site classification:** Peak (roadside) \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Wind measurements will be perturbed by elevated ground and roadways to the north and west of the monitoring site. \r\n\r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacative ceramic sensor \r\n**Relative humidity:** Capacitive thin film polymer sensor \r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1 \r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**Carbon monoxide:** Infrared absorption analyser operated in accordance with AS 3580.7.1\r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13\r\n\r\n* The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter. \r\n* Reported concentrations are uncorrected instrument output values. \r\n* The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.\r\n* Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported. \r\n\r\n
South Gladstone (Gladstone) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018\r\n**Site location:** Latitude: -23.8627; Longitude: 151.2704 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Isolated trees within 20 metres of the monitoring site. \r\n* Temperature and relative humidity sensors located 10 metres above ground level \r\n* Rainfall measured by acoustic sensor. \r\n\r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacitive ceramic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Barometric pressure:** Capacitive silicon sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Solar radiation:** Pyranometer \r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1\r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1\r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13\r\n\r\n* The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter. \r\n* Reported concentrations are uncorrected instrument output values. \r\n* The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.\r\n* Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported. \r\n\r\n**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1:2001 \r\n\r\n* Detector spectral response centred at 530 nm. \r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n
Southport (South East Queensland) 2018 hourly air quality and meteorological data - **Period of operation:** 23 February (site established) to 31 December 2018 \r\n**Site location:** Latitude: -27.9612; Longitude: 153.4024 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies, except for: \r\n\r\n* Buildings below height of inlet within 5 metres north and east of the monitoring site \r\n* Isolated trees above height of inlet within 20 metres south of the monitoring site \r\n\r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Isolated trees within 20 metres south of the monitoring site. \r\n* Temperature and relative humidity sensors located 10 metres above ground level. \r\n* Rainfall measured by acoustic sensor. \r\n\r\n**Wind: Ultrasonic sensor** \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacitive ceramic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Barometric pressure:** Capacitive silicon sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Ozone:** UV absorption analyser operated in accordance with AS/NZS 3580.6.1 \r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1 \r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**Carbon monoxide (until 28 September):** Infrared absorption analyser operated in accordance with AS 3580.7.1 \r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13 \r\n\r\n* The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter. \r\n* Reported concentrations are uncorrected instrument output values. \r\n* The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals. \r\n* Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.
Springwood (South East Queensland) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018\r\n**Site location:** Latitude: -27.6125; Longitude: 153.1359 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies, except for: \r\n\r\n* Trees above height of PM10/PM2.5 inlets within 5 metres south and west of the monitoring site. \r\n\r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Located below the upper level of a ridge running roughly northwest-southeast. \r\n* Trees within 10 metres of the monitoring site (below height of wind sensor). \r\n\r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacitive ceramic sensor \r\n\r\n* Height above ground level: 3 metres. \r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor \r\n\r\n* Height above ground level: 3 metres. \r\n\r\n**Barometric pressure:** Capacitive silicon sensor \r\n\r\n* Height above ground level: 3 metres. \r\n \r\n**Ozone, nitric oxide, nitrogen dioxide, sulfur dioxide, benzene, toluene, xylenes (total) and formaldehyde:** Differential Optical Absorption Spectroscopy (DOAS) analyser operated in accordance with AS/NZS 3580.15 \r\n\r\n* Values are average concentrations over 250 metre light path running east-west from (-27.6117, 153.1382) to (-27.6125, 153.1359). \r\n* Instrument output offset and/or scaled based on instrument calibration data. \r\n\r\n**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13 \r\n\r\n* The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter. \r\n* Reported concentrations are uncorrected instrument output values. \r\n* The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals. \r\n* Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported. \r\n
Stuart (Townsville) 2018 hourly air quality and meteorological data - **Industry-operated monitoring site:** Raw data received from industry validated by Queensland Government\r\n**Period of operation:** 1 January to 14 November 2018 (site closed) \r\n**Site location:** Latitude: -19.3212; Longitude: 146.8422 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14: compliance (meteorology):** Complies fully, except for:\r\n \r\n* Temperature and relative humidity sensors located 10 metres above ground level.\r\n* Rainfall measured by acoustic sensor.\r\n\r\n**Temperature:** Capacitive ceramic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Barometric pressure:** Capacitive silicon sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1. \r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data.
Tara Region (South West Queensland) 2018 hourly air quality data - **Industry-operated monitoring site:** Data presented as received by Queensland Government \r\n**Period of operation:** 1 January to 31 December 2018 (NO and NOx measurement data supplied from 5 March 2018) \r\n**Site location:** 26 km south-southeast of Condamine town centre \r\n**AS/NZS 3580.1.1 site classification:** Background \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies \r\n**Ozone:** Ultraviolet photometry analyser operated in accordance with AS 3580.6.1 \r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1 \r\n**Carbon Monoxide:** Infrared absorption analyser operated in accordance with AS 3580.7.1
Targinie (Gladstone) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018\r\n**Site location:** Latitude: -23.7743; Longitude: 151.1060 \r\n**AS/NZS 3580.1.1 site classification:** Background \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Trees within 15 metres north west of the monitoring site. \r\n* Temperature and relative humidity sensors located 10 metres above ground level.\r\n* Rainfall measured by acoustic sensor. \r\n\r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacitive ceramic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Barometric pressure:** Capacitive silicon sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1 \r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1\r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13\r\n\r\n* The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter. \r\n* Reported concentrations are uncorrected instrument output values. \r\n* The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.\r\n* Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported. \r\n\r\n**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1 \r\n\r\n* Detector spectral response centred at 530 nm. \r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data.
The Gap (Mount Isa) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -20.7264; Longitude: 139.4977 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n \r\n* Buildings higher than wind sensor located within 20 metres north east and east of the monitoring site. \r\n* Monitoring shelter located on concreted surface. \r\n\r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +6 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacitive ceramic sensor \r\n\r\n* Height above ground level: 3 metres. \r\n\r\n**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1 \r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**PM10:** Tapered Element Oscillating Balance (TEOM) Model 1405 operated in accordance with AS/NZS 3580.9.16 (excluding FDMS requirements)\r\n\r\n* Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.\r\n* Reported concentrations are uncorrected instrument output values.\r\n* Negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.\r\n
Townsville Coast Guard (Townsville) 2018 hourly air quality and meteorological data - **Joint Queensland Government / industry-operated monitoring site:** Data validation conducted by the Queensland Government. \r\n**Period of operation:** 1 January to 31 December 2018 \r\n**Site location** Latitude: -19.2542; Longitude: 146.8257 \r\n**AS/NZS 3580.1.1 site classification:** Peak (port operations) \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Trees within 5 metres to the west of the industry/joint monitoring station (no obstructions in direction of port operations). \r\n* Monitoring station located on asphalt surface. \r\n* Temperature and relative humidity sensors located 10 metres above ground level.\r\n* Rainfall measured by acoustic sensor.\r\n\r\n**Wind sensor:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Temperature:** Negative temperature coefficient (NTC) thermistor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor\r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Rainfall:** Doppler radar \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Barometric pressure:** MEMS capacitive pressure sensor\r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Solar radiation:** Thermopile\r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**PM10:** Scattered light spectrometry (TAPI Model 640X) operated in accordance with USEPA equivalence method designation requirements \r\n\r\n* Reported concentrations are uncorrected instrument output values. \r\n\r\n**TSP:** Tapered Element Oscillating Microbalance (TEOM) Model 1405 fitted with TSP inlet and operated in accordance with AS/NZS 3580.9.16 (excluding FDMS requirements)\r\n\r\n* Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.\r\n* Reported concentrations are uncorrected instrument output values. \r\n* Negative hourly TSP concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.\r\n
Townsville Lennon Drive (Townsville) 2018 hourly air quality and meteorological data - **Industry-operated monitoring site:** Data presented as received by Queensland Government \r\n**Period of operation:** 24 May (site established) to 31 December 2018 \r\n**Site location:** Latitude: -19.2589; Longitude: 146.8264 \r\n**AS/NZS 3580.1.1 site classification:** Peak (port operations) \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Temperature and relative humidity sensors located 10 metres above ground level.\r\n* Rainfall measured by acoustic sensor.\r\n\r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Temperature:** Negative temperature coefficient (NTC) thermistor \r\n\r\n* Height above ground level: 10 metres.\r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor \r\n\r\n* Height above ground level: 10 metres.\r\n\r\n**Rainfall:** Doppler radar \r\n**Barometric pressure:** MEMS capacitive pressure sensor \r\n**Solar radiation:** Thermopile \r\n**PM10:** Scattered light spectrometry (TAPI Model 640X) operated in accordance with USEPA equivalence method designation requirements \r\n\r\n* Reported concentrations are uncorrected instrument output values.
West Mackay (Mackay) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -21.1596; Longitude: 149.1550 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies fully \r\n\r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +9 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacitive ceramic sensor \r\n**PM10:** Tapered Element Oscillating Balance (TEOM) Model 1405 operated in accordance with AS/NZS 3580.9.16 (excluding FDMS requirements)\r\n\r\n* Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.\r\n* Reported concentrations are uncorrected instrument output values. \r\n* Negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.\r\n\r\n**Visibility-reducing particles:** Nephelometer operated in accordance with AS/NZS 3580.12.1\r\n\r\n* Detector spectral response centred at 530 nm.\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data.\r\n
Woolloongabba (South East Queensland) 2018 hourly air quality and meteorological data - **Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -27.4975; Longitude: 153.0350 \r\n**AS/NZS 3580.1.1:2007 site classification:** Peak (roadside) \r\n**AS/NZS 3580.1.1:2007 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14:2011 compliance (meteorology):** Complies, except for: \r\n\r\n* Railway overpass embankment located within 20 metres north of the monitoring site.\r\n* Elevated busway and 4-storey busway station building located within 30 metres south to southwest of the monitoring site.\r\n* No obstructions in direction of roadway.\r\n* Temperature and relative humidity sensors located 10 metres above ground level.\r\n* Rainfall measured by acoustic sensor.\r\n \r\n**Wind:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n* The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value. \r\n\r\n**Temperature:** Capacitive ceramic sensor\r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor\r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Barometric pressure:** Capacitive silicon sensor\r\n\r\n* Height above ground level: 10 metres. \r\n \r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1\r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data.\r\n\r\n**Carbon monoxide:** Infrared absorption analyser operated in accordance with AS 3580.7.1\r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data.\r\n\r\n**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13 \r\n\r\n* The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter. \r\n* Reported concentrations are uncorrected instrument output values. \r\n* The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.\r\n* Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.
Wynnum North (South East Queensland) 2018 hourly air quality and meteorological data - **Industry-operated monitoring site:** Data presented as received by Queensland Government \r\n**Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -27.4296; Longitude: 153.1581 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies fully \r\n**AS/NZS 3580.14 compliance (meteorology):** Complies fully \r\n\r\n* Temperature and relative humidity sensors located 10 metres above ground level.\r\n* Rainfall measured by acoustic sensor.\r\n\r\n**Wind sensor:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Temperature:** Capacitive ceramic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Barometric pressure:** Capacitive silicon sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Oxides of nitrogen:** Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1\r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1\r\n \r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-D operated in accordance with AS/NZS 3580.9.13 (excluding FDMS requirements)\r\n\r\n* Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter. \r\n* Reported concentrations are uncorrected instrument output values. \r\n* Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.\r\n
Wynnum West (South East Queensland) 2018 hourly air quality and meteorological data - **Industry-operated monitoring site:** Data presented as received by Queensland Government\r\n**Period of operation:** 1 January to 31 December 2018 \r\n**Site location:** Latitude: -27.4379; Longitude: 153.1495 \r\n**AS/NZS 3580.1.1 site classification:** Neighbourhood \r\n**AS/NZS 3580.1.1 compliance (pollutants):** Complies, except for: \r\n \r\n* Trees higher than sample inlets within 10m north-west of monitoring station. \r\n* Building below height of sample inlets within 10m east of monitoring station. \r\n\r\n**AS/NZS 3580.14 compliance (meteorology):** Complies, except for: \r\n\r\n* Trees within 10m north-west of monitoring station. \r\n* Building below height of wind sensor within 10m east of monitoring station. \r\n* Temperature and relative humidity sensors located 10 metres above ground level. \r\n* Rainfall measured by acoustic sensor. \r\n\r\n**Wind sensor:** Ultrasonic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Temperature:** Capacitive ceramic sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Relative humidity:** Capacitive thin film polymer sensor \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Rainfall:** Vaisala RAINCAP® precipitation sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Barometric pressure:** Capacitive silicon sensor. \r\n\r\n* Height above ground level: 10 metres. \r\n\r\n**Sulfur dioxide:** Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1. \r\n\r\n* Instrument output offset and/or scaled based on calibration and daily zero/span response data. \r\n\r\n**PM10/PM2.5:** Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-D operated in accordance with AS/NZS 3580.9.13 (excluding FDMS requirements)\r\n\r\n* Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter. \r\n* Reported concentrations are uncorrected instrument output values. \r\n* Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.\r\n
Subjects
User Contributed Tags
Login to tag this record with meaningful keywords to make it easier to discover
Identifiers
- Local : air-quality-monitoring-2018
- URI : data.qld.gov.au/dataset/489af055-2f85-413d-8543-4b8817d15d93