Data

Microstructures of cold-sprayed titanium before and after heat treatment

Commonwealth Scientific and Industrial Research Organisation
Ren, Yuqi ; Yang, Sam ; King, Peter ; Xiao, Tiqiao ; Chu, Clement ; Gulizia, Stefan ; Murphy, Tony ; Stevenson, Andrew
Viewed: [[ro.stat.viewed]] Cited: [[ro.stat.cited]] Accessed: [[ro.stat.accessed]]
ctx_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rfr_id=info%3Asid%2FANDS&rft_id=info:doi10.25919/rp5r-ka97&rft.title=Microstructures of cold-sprayed titanium before and after heat treatment&rft.identifier=10.25919/rp5r-ka97&rft.publisher=Commonwealth Scientific and Industrial Research Organisation (CSIRO)&rft.description=A conical-shaped pin of cold sprayed titanium was prepared using a CGT Kinetiks 4000 system. After a synchrotron X-ray micro-CT scan the titanium pin was heat treated at 850 degree C for 4 hours. The second micro-CT scan was performed. Both X-ray CT data were analysed using DCM for their 3D porosity distributions.&rft.creator=Ren, Yuqi &rft.creator=Yang, Sam &rft.creator=King, Peter &rft.creator=Xiao, Tiqiao &rft.creator=Chu, Clement &rft.creator=Gulizia, Stefan &rft.creator=Murphy, Tony &rft.creator=Stevenson, Andrew &rft.date=2021&rft.edition=v16&rft_rights=All Rights (including copyright) CSIRO 2017.&rft_rights=Creative Commons Attribution-NonCommercial-No Derivatives https://creativecommons.org/licenses/by-nc-nd/4.0/&rft_subject=Cold sprayed titanium, data-constrained modelling, DCM, heat treatment, porosity&rft_subject=Metals and Alloy Materials&rft_subject=ENGINEERING&rft_subject=MATERIALS ENGINEERING&rft_subject=Software Engineering&rft_subject=INFORMATION AND COMPUTING SCIENCES&rft_subject=COMPUTER SOFTWARE&rft.type=dataset&rft.language=English Access the data

Licence & Rights:

Non-Derivative Licence view details
CC-BY-NC-ND

Creative Commons Attribution-NonCommercial-No Derivatives
https://creativecommons.org/licenses/by-nc-nd/4.0/

All Rights (including copyright) CSIRO 2017.

Access:

Open view details

Data is accessible online and may be reused in accordance with licence conditions

Brief description

A conical-shaped pin of cold sprayed titanium was prepared using a CGT Kinetiks 4000 system. After a synchrotron X-ray micro-CT scan the titanium pin was heat treated at 850 degree C for 4 hours. The second micro-CT scan was performed. Both X-ray CT data were analysed using DCM for their 3D porosity distributions.

Data time period: 2017-08-09

This dataset is part of a larger collection

Click to explore relationships graph
Identifiers